Bussmann BP/FRNR-60 Heavy-Duty Fuse, 60 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body, K, Time Delay Fuse

Category Fuses
6195143

Bussmann BP/FRNR-60 Heavy-Duty Fuse, 60 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body, K, Time Delay Fuse

Item Code: 6195143
Category Fuses
Manufacturer Bussmann

Description

Bussmann Series Fusetron cartridge fuses are 23% more energy-efficient and offer the excellent time delay performance. Their dual element feature allows closer sizing to load for great protection of motors and transformers. These Class RK5 fuses with a 200 kA interrupting rating can be used in a broad range of applications. When sized correctly, they help protect motors from burnout caused by overloads or single phasing. The time delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present.

Specifications

UNSPSC Code

35.353.353

Weight

0.24lb

Height

2.88in

Width

4.5in

Length

6.13in

Body Material

Fiberglass

Current Rating

60 A

Diameter

13/16 in

Element Type

Dual

Fuse Group

K

Fuse Type

Time Delay

Indicator Type

Non-indicating

Interrupt Rating

20 200 kA

Length

3

Rejection/Non-Rejection

Rejection

Terminal Type

Ferrule

Voltage Rating

250 VAC 125 VDC

Call for price
Starting from
$34.05 / CD 2
/
- +
Your Pick-up branch is Kasten Building Supply, Jackson
Compare

Bussmann BP/FRNR-60 Heavy-Duty Fuse, 60 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body, K, Time Delay Fuse

Category Fuses
6195143

Bussmann BP/FRNR-60 Heavy-Duty Fuse, 60 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body, K, Time Delay Fuse

Item Code: 6195143
Category Fuses
Manufacturer Bussmann

Description

Bussmann Series Fusetron cartridge fuses are 23% more energy-efficient and offer the excellent time delay performance. Their dual element feature allows closer sizing to load for great protection of motors and transformers. These Class RK5 fuses with a 200 kA interrupting rating can be used in a broad range of applications. When sized correctly, they help protect motors from burnout caused by overloads or single phasing. The time delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present.

Specifications

UNSPSC Code

35.353.353

Weight

0.24lb

Height

2.88in

Width

4.5in

Length

6.13in

Body Material

Fiberglass

Current Rating

60 A

Diameter

13/16 in

Element Type

Dual

Fuse Group

K

Fuse Type

Time Delay

Indicator Type

Non-indicating

Interrupt Rating

20 200 kA

Length

3

Rejection/Non-Rejection

Rejection

Terminal Type

Ferrule

Voltage Rating

250 VAC 125 VDC